Fireplace insert with air jacket Prity TCF - 26 kW
Delivery estimate
• 5–7 business days – Central Europe
• 7–10 business days – Western Europe
• 10–12 business days – Northern & Southern Europe
✔ Secure pallet delivery
✔ Tracking number provided
✔ Delivery confirmation before arrival
Delivery times are estimates and may vary by destination.
Need help? Contact our team before ordering.
Technical Specifications
Dimensions: W X D X H
Firebox size: W X D X H
Weight:
Flue pipe diameter:
Heat output: 26 kW
Boiler: No
Air jacket: Yes
Air ducts: 4 x Ø128 mm
Heated area: Up to 200 m²
Energy efficiency:
81.8 %
Przepustnica Spalin
Przepustnica spalin reguluje ciąg kominowy. Otwórz ją całkowicie podczas rozpalania ognia lub doaładowania, aby dym prawidłowo się wydobywał. Gdy ogień się ustabilizuje, częściowe zamknięcie spowalnia ciąg i wydłuża czas palenia.
Regulacja Powietrza Pierwotnego
Regulacja powietrza pierwotnego kontroluje przepływ powietrza do podstawy paleniska, zasilając ogień bezpośrednio od dołu. Przesuń dźwignię w lewo, aby zamknąć, lub w prawo, aby otworzyć — płaskie narzędzie, takie jak śrubokręt, ułatwia dostęp i regulację.
Otwórz powietrze pierwotne całkowicie podczas rozpalania ognia lub doaładowania, aby szybko zbudować silny płomień. Gdy ogień się ustabilizuje, zamknij je, aby spowolnić spalanie i przełącz się na powietrze wtórne i trzeciorzędne dla czystszego, bardziej wydajnego spalania.
Korzystanie z Wentylatora
① Regulator prędkości kontroluje, jak szybko pracuje wentylator, od 0 (wyłączony) do 4 (maksimum). Dostosuj go do ilości ciepłego powietrza, które chcesz cyrkulować.
② Przełącznik wentylatora ma dwa ustawienia: [wł.] uruchamia wentylator nieprzerwanie z wybraną prędkością, natomiast [wył.] pozwala termostatowi automatycznie sterować wentylatorem, włączając go dopiero po osiągnięciu przez wkładkę temperatury roboczej.
Wykładzina Komory: Zostaw Miejsce na Dostęp Serwisowy
Podczas wykładania komory zostaw otwory serwisowe (drzwiczki) dla ① i ②:
① Właz dostępowy — otwór umożliwiający dostęp do włazu serwisowego używanego do czyszczenia komory.
② Otwór do wyjmowania wentylatora — wystarczająco duży, aby wentylator turbinowy ③ mógł zostać przez niego wyciągnięty, jeśli kiedykolwiek będzie wymagał serwisu lub wymiany.
Pominięcie tych otworów teraz oznacza wycinanie w gotowej komorze później.
Prity TCF Panoramic Fireplace Insert with Air Jacket – 26 kW
Fire on Three Sides. Heat Throughout the House.
The Prity TCF is built for homes that want the fire to be the centerpiece and the heat to reach well beyond the room it's in. Its panoramic three-sided glass door turns the firebox into a genuine visual feature — flames visible from the front and both angled side panels, rather than through a single flat window. Behind that glass sits one of the most powerful heating systems in the Prity range: 7 kW of direct radiant heat plus a 19 kW heat exchanger, for a combined output of 26 kW.
A built-in fan drives warm air through four Ø128 mm ducts — twice as many as our standard air jacket inserts — letting you distribute heat to multiple rooms from a single fire, not just the one where the insert is installed.
How Much Space Can It Heat?
The TCF is suitable for heating spaces of up to 200 m², depending on insulation, ceiling height, room layout, and how the four ducts are distributed across your home. Its combined radiant and forced-air output makes it a genuine whole-home heating solution rather than a single-room insert.
Panoramic Glass: Fire as a Feature, Not Just a Function
Most fireplace inserts show the fire through a single front window. The TCF's door wraps around three sides of the firebox, so the flames are visible from a much wider range of angles in the room. Combined with the insert's wide, shallow firebox — 910 × 450 × 255 mm — this creates a broad, low band of visible fire rather than a tall narrow window, well suited to a wide chimney breast or a fireplace designed as the focal point of an open-plan room.
The Air Jacket: One Fire, Four Ducts, Multiple Rooms
Cool air is drawn into the chamber surrounding the firebox, heated as it circulates, and pushed out through four Ø128 mm ducts by a built-in fan. A speed regulator controls airflow intensity, and a switch lets you choose between continuous forced operation or automatic thermostat control, which runs the fan only once the insert has reached operating temperature. Each duct can be routed independently, so warm air can reach several rooms from a single installation — well beyond what the direct radiant heat alone would cover.
This forced-air system works alongside the insert's 7 kW of direct radiant heat, which continues to warm the room through the panoramic glass regardless of how the ducted air is distributed.
Clean, Efficient Combustion
The TCF returns a flue gas temperature of 211°C and an overall efficiency of 81.8%, with a seasonal space heating energy efficiency (ηs) of 73.0% — evidence that the heat exchanger is genuinely extracting energy from the fire rather than letting it escape up the flue. Emissions at nominal output are CO 1009 mg/Nm³, dust 32 mg/Nm³, NOx 89 mg/Nm³, and OGC 33 mg/Nm³, all measured at 13% O2, within EU Ecodesign limits.
Fuel consumption runs at just 2.4 kg/h at nominal power — notably efficient for a unit delivering 26 kW combined output.
Installation Requirements
The TCF uses a Ø200 mm flue outlet and requires a minimum chimney draught of 12 Pa. As with all fireplace inserts, installing a flexible stainless steel liner inside your existing chimney is necessary to ensure safe and efficient operation — your existing chimney flue alone is rarely sufficient. A qualified installer will assess your chimney and confirm the correct liner diameter before installation.
The fan requires a standard electrical connection near the installation site. At 202 kg, this is the heaviest insert in our range — professional installation is strongly recommended, and you should confirm your fireplace opening can accommodate the TCF's dimensions, including clearance for all four ducts, before ordering.
30 Years of European Engineering Behind Every Weld
Prity has been manufacturing solid fuel heating appliances in Gorna Oryahovitsa, Bulgaria since 1995. With over 250 production workers and a product range refined over three decades, they build inserts that earn their place in a home for many years. Every unit is manufactured to EN 13229, the European standard for fireplace inserts, including open fires burning solid fuels.
Your TCF comes with a 24-month manufacturer's warranty.
Everything You Get
• Combined heat output of 26 kW (7 kW radiant + 19 kW via heat exchanger) — suitable for spaces up to 200 m², depending on insulation, ceiling height, and duct distribution
• Panoramic three-sided glass door — fire visible from front and both angled side panels
• Built-in air jacket with four Ø128 mm ducts and a variable-speed fan — distribute warm air to multiple rooms, with manual or thermostat-controlled operation
• Energy Class A+ with an EEI of 110 and a seasonal heating efficiency of 73.0%
• 81.8% efficiency with fuel consumption of just 2.4 kg/h at nominal power
• Wide, shallow firebox (910 × 450 × 255 mm) for a broad panoramic view of the fire
• Flue gas temperature of 211°C
• Ø200 mm flue outlet
• Overall dimensions: 1080 × 600 × 1050 mm
• Net weight: 202 kg
• 24-month warranty
What's in the Box
Insert body with integrated air jacket and four air ducts, fan unit with speed regulator and thermostat switch, panoramic door with heat-resistant glass, ash removal tool, technical manual. A flexible stainless steel chimney liner is not included and should be sourced separately based on your installer's assessment.
Use only dry, chemically untreated natural wood or wood briquettes without adhesives. Wood moisture content must not exceed 20%. Do not burn household waste, painted wood, plywood, or impregnated timber. Installation must be carried out by a qualified professional, including assessment of your chimney and installation of an appropriate flue liner. Always consult a qualified installer before connecting to your chimney system. Note: this model weighs 202 kg — professional installation is required.